GS1 DataMatrix, QR, Data Matrix and GS1-128, EAN-13 and ITF-14 are supported down to a 0.25 mm module. Each batch produces a grade record to ISO/IEC 15415 or 15416 on the A to D scale, with direct part marks assessed under ISO/IEC TR 29158.
Medical-grade software linked to the UDI database
UDI-DI and UDI-PI fields such as lot, serial, production and expiry dates are issued by the database and only executed by the machine, so numbers are never edited by hand. Errors trace to a batch and an operator, and exported records drop straight into the quality file.
Fully enclosed beam path and cleanroom configuration
A dust cover over the beam path, internal negative-pressure extraction with HEPA filtration and a separate lens cavity keep the machine usable in an ISO Class 7 cleanroom, with exhaust routed away from the work area.
No carbonising on heat-sensitive or thin-wall parts
Walls down to 0.5 mm, film down to 0.05 mm and PEEK, PE or PP parts stay undistorted, with a heat-affected zone within 20 μm; codes survive alcohol wiping and ultrasonic cleaning.
Applications
On small, low-value parts loaded by hand, vision saves fixtures and alignment time. Where each part needs long marking time, or a field beyond 150 mm for arrays, the 20 W cycle time becomes the bottleneck.
Power towers and lines
Tower and cross-arm numbers and earthing marks on angle steel, worked at height with no mains
01
Pipelines and valves
Weld-joint codes, pipe section numbers and valve tags on lines already insulated or in position
02
Heavy steel and wind
Member numbers, tower section codes and flange batch marks, recessed to 0.05 mm to survive grinding
03
Vessels and rail vehicles
Compartment marks, car-body steel codes and bogie part numbers in confined spaces without dismantling
04
Non-metal site work
Cable and fibre sheathing numbers, plastic pipe specification codes and installed glass serials, marked without scorching
05
Process Boundaries




Materials: stainless and titanium instruments, PEEK, PE/PP/PVC consumables, glass and quartz tubes and cuvettes, Tyvek and paper-plastic packaging film and some ceramics. Typical processes: UDI linear and 2D codes, lot and serial numbers, high-density Data Matrix and shallow instrument surface marks. Not applicable: deep metal engraving, cutting, removal beyond 0.05 mm or rough-line coding outside controlled environments.
Configurations
|
Model |
Source |
Power |
Field |
Role |
|
HT-MD-UV-355-05 |
UV 355 nm |
5 W |
Benchtop 70–150 mm |
Instruments, reagent tubes, thin-wall parts one at a time |
|
HT-MD-UV-355-10 |
UV 355 nm |
10 W |
Benchtop 70–150 mm |
Consumable batches and instrument serial volume |
|
HT-MD-IL-355-10 |
UV 355 nm, in-line |
10 W |
Custom per station |
Flying marks on pouches and label areas in line |
FAQ
Q: What is included in the validation package for UDI laser coding?
A: Installation and operational qualification templates, a frozen-parameter table covering power, frequency, speed and hatch, read-grade and adhesion records, cleaning and sterilisation test methods and a change-control sheet. Performance qualification runs on the customer's own product and process and is not performed by us.
Q:How is UDI code readability ensured, and how is the grade judged?
A: A stepped parameter sample is run on the customer's part and the setting with the best grade and passing adhesion is frozen. 2D codes are graded to ISO/IEC 15415 and linear codes to ISO/IEC 15416, with grade C or 1.5 as the pass line; direct part marks follow ISO/IEC TR 29158. Production rechecks the first piece of each batch.
Q: Do sterilisation and repeated cleaning remove the mark?
A: Cold ablation creates a surface microstructure rather than a coating, so codes remain readable after ethylene oxide, gamma and steam sterilisation, and survive alcohol, isopropanol and ultrasonic cleaning. Strong alkali immersion and mechanical brushing wear it, and such applications must assess that during validation.
Q: How is a UDI coding machine set up in a cleanroom
A: A dust cover, internal negative-pressure extraction with HEPA and exhaust routed out of the clean zone keep the lens cavity separate from the work area, and lens changes happen outside the cover. Dimensions, power draw and exhaust volume are provided ahead of installation for layout and acceptance.
Q: Does slide marking affect reading or scanning?
A: Marking runs only on the frosted or label end, leaving the coverslip and tissue area untouched; at 1.2 to 2 mm high and ≤10 μm deep it does not disturb whole-slide imaging focus after coverslipping. The pathology number and barcode stay legible through xylene dewaxing, ethanol gradients and antigen retrieval, and grading follows ISO/IEC 15415 with grade C or 1.5 as the pass line.
Hot Tags: ht-md medical coding edition, China ht-md medical coding edition manufacturers, suppliers, factory
Technical Specifications
|
Item |
Specification |
|
Source |
UV 355 nm at 5 or 10 W as standard, with optional fiber 1064 nm 20 W or CO2 10.6 μm 30 W |
|
Symbologies |
GS1 DataMatrix,QR,Data Matrix;GS1-128, EAN-13 and ITF-14 for linear |
|
Minimum module |
0.25 mm |
|
Quality grading |
ISO/IEC 15416 for linear, ISO/IEC TR 29158 for direct part marking |
|
Acceptance grade |
Grade C or better, or 1.5 and above |
|
Software |
Medical-grade coding software linked to the UDI database with UDI-DI and UDI-PI traceability |
|
Form |
Standalone UV-355-05 or -10, or in-line IL-355-10, one or the other |
|
Working field |
70×70 to 150×150 mm standalone; custom per station in line |
|
Heat-affected zone |
Within 20 μm by cold ablation |
|
Cleaning |
Survives alcohol and isopropanol wiping and ultrasonic cleaning |
|
Cleanroom fit |
Enclosed beam path, negative-pressure extraction with HEPA, dust cover |
|
Validation |
templates, frozen-parameter table, read-rate and adhesion methods, change-control sheet |
|
Cooling and power |
Air-cooled; single-phase 220 V 50 Hz |